Residential Design Services - Permit Package

CS part #
cs-301292
Mfr. part #
Residential Design Services - Permit Package

Description

Service Description
 

*Project Details:

  • Residential PV Only Project
  • 240 VAC Split Phase Service Voltage
  • 1 Point of Interconnection
  • System size <20kW and no service side connection is required for installation
  • No Generator 
  • No Energy Storage
  • Modules, Inverters, Racking and MLPE Equipment Used Must be in CivicSolar Catalogue
  • Licenced Installer
  • Existing Structure Visible on Satellite Images (if applicable)
  • Roof is "Standard Construction" and does not require a structural PE stamp.
*Any variance will require a Custom Permit Set SKU

Required Information:
  • Completed Project Intake Form
  • Site Sketch including
    • Array Layout
    • Meter, Service Panel & Equipment Locations
  • Site Pictures

Services to be provided(Scope of Work):

CivicSolar shall prepare design drawings in accordance with our Terms and Conditions

  1. Title Sheet & Notes

  2. Site Plan Sheet

  3. Module Layout and Attachement Detail

  4. Electrical Layout Sheet

  5. Electrical Diagram & Cable Schedule

  6. Placards Sheet

  7. Solar Equipment Datasheets

 

Exclusions:

  1. Any items not specifically included in the detailed scope of work.

  2. Creating or editing formal Equipment Specifications.

  3. Multiple design iterations with Contractor/Client for Value Engineering.

  4. Representing or incorporating Vendor shop drawings in Plan Sets.

  5. Design and Engineering of Array or String level monitoring, of any custom data acquisition or monitoring equipment, SCADA System Architecture design and specification, for lighting systems, for lightning protection systems or modifications to existing lightning protection systems, of Substations and Switchyards, of Electrical Modifications or Upgrades to existing Electrical gear, of site-specific ground-grid design

  6. AC/DC Arc-Flash or Short Circuit Calculations.

  7. Fuse coordination or protection studies.

  8. System Impact and Reliability Studies, Feasibility Studies, and other Utility required studies for interconnection.

  9. Alterations to the existing site beyond the solar farm / solar array boundaries.

  10. Providing, generating, or certifying existing roof/structure As-Built conditions.

  11. Design and analysis of PV racking systems. We expect to be using a pre-engineered racking structure from the vertical post upward.

  12. Engineering for Structural Modifications or Upgrades.

  13. Permit costs or any other required jurisdictional permits.  Utility interconnection fees or costs. Submittals or coordination with Authority Having Jurisdiction or Utility.  

  14. Signing or certifying “Record Drawings”.

  15. Construction Administration or oversight.

  16. Design or production of more than one (1) distinct plan set or one (1) interconnection point, unless specified in this scope of work.

 

Deliverables:
*All files to be provided in digital PDF format. Printing and shipping shall be invoiced on a time and materials basis.