  1. If the inverter is too far away for bluetooth connection, is there a way to monitor an array via cat5 connection?

    Asked 07/11/2011

    If the inverter is too far away for bluetooth connection, is there a way to monitor an array via cat5 connection?   

    Question – 5 comments

  2. Why buy an inverter with charger combination if you need to buy a charge controller?

    Asked 07/11/2011

    Why buy an inverter with charger combination if you need to buy a charge controller?

    Question – 1 comment

  3. Do you have an installation manual for the DECK Monitoring and for the Weather Station system?

    Asked 07/08/2011

    I am installing a DECK monitoring system on a job and I am looking for the installation manual for the Deck Monitoring and for the Weather

    Question – 1 comment

  4. Is there a substitute for Xantrex Prosine 3.0 Inverter/Charger?

    Asked 07/06/2011

    Is there a really good substitute for  Xantrex Prosine 3.0 Inverter / Charger 3000w Pure Sinewave  product? Please advise.

    Question – 1 comment

  5. What is the difference between the SMA 2500 inverters?

    Asked 06/30/2011

    I am looking for a 2.5 kw inverter.

    Question – 1 comment

  6. What is the best substitute for Sharp 170W solar panel?

    Asked 06/29/2011

    I currently have a small installation of Sharp 170W panels.

    Question – 1 comment

  7. What are the options for a grid-tied array to continue to generate power in the event of a power outage?

    Asked 06/27/2011

      Hello, I'd like to get a better understanding of the ability of a grid-tied system to produce power when the g

    Question – 2 comments

  8. How do you calculate the efficiency of a solar panel?

    Asked 06/27/2011

    Solar Panel data sheets show both cell efficiency and module efficiency.   How do you calculate module efficiency?  Do you include the sol

    Question – 1 comment

  9. How much clearance is required when mounting a Sunny Boy 6000?

    Asked 06/24/2011

    I'm installing a Sunny Boy 6000 on a job, but have limited area to mount the inverter.  What is the required clearance?

    Question – 2 comments

  10. What is the wind resistance rating required by IEC 61215?

    Asked 06/24/2011

    I'm using a  Siliken SLK60P6L 230 Solar Panel  on a project in a coastal area prone to hurricanes.

    Question – 1 comment

  11. In what applications are Tyco Solklips best utilized?

    Asked 06/24/2011

    Hello, I'd like to get a better understanding of what applications are best served by using Tyco Solklips.

    Question

  12. What are the Deck Monitoring components I should specify for a commercial job using multiple SMA Sunny Boy inverters?

    Asked 06/23/2011

    We're developing a project that will use a mix of four SMA Sunny Boy inverters.

    Question – 1 comment

  13. What is the start voltage of the Steca Solsum 6.6f?

    Asked 06/23/2011

    I've looked through the  Steca Solsum 6.6F 6A Charge Controller 's data sheet and install manual, and I haven't been ab

    Question – 1 comment

  14. Are the 1/2" strain relief bushings intended for a 7/8” hole?

    Asked 06/23/2011

    I am looking at 2 hole 1/2" hub strain relief bushings for #10 USE-2 wire.   The question is are they intended for a 7/8" hole o

    Question – 1 comment

  15. Can you sub out the 175A breaker in a MidNite Solar MNE175LT E-Panel?

    Asked 06/23/2011

    I recently purchased the  MidNite Solar MNE175LT E-Panel , but have since found that I only need 125A protection.

    Question – 1 comment

  16. How do you estimate the string sizing for the Xantrex XW MPPT 80-600 Charge Controller?

    Asked 06/22/2011

    I noticed that Xantrex has not yet published the string sizing tool for the Xantrex XW MPPT 80-600 .   What's a good way to estima

    Question – 2 comments

  17. What Combiner Box with AC Disconnect do you recommend for Enphase branch lines?

    Asked 06/22/2011

    What AC Combiner Box with AC Disconnect do you recommend for up to 12 incoming Enphase branch lines?

    Question – 1 comment

  18. Compatibility of Magnum Energy ME-ARC50 Remote Control

    Asked 06/22/2011

    If you are thinking of buying the  Magnum Energy ME-ARC50 Remote Control to use with your Magnum inverter, visit the Magnum Energy webs

    Question – 1 comment

  19. Why would my new Deka batteries be showing less than a full charge?

    Asked 06/21/2011

    I just installed a 3-panel system along with (2) Deka 12V 245Ah AGM batteries.  The system is working great.

    Question – 3 comments

  20. Can you use a solar inverter for a wind installation?

    Asked 06/20/2011

    Are there any solar inverters which can be used with wind turbines?

    Question – 2 comments

  21. What is the difference between the Enphase Envoy IEMU-02 and IEMU-03 gateways?

    Asked 06/20/2011

    I am buying a Enphase Envoy IEMU Communications Gateway and I need to know the difference between the IEMU -02 and the IEMU -03 versions? 

    Question – 1 comment

  22. Does the MidNite Solar MNPV6 Combiner Box come with a Ground Bus Bar?

    Asked 06/16/2011

    I am buying MidNite Solar MNPV6 Combiner 6 Input 20A 150/600V for combining 6 strings light commercial solar project.

    Question – 2 comments

  23. On the Apollo Solar Charge Controller, what are the steps to fix a high input Voltage Error?

    Asked 06/16/2011

    We have an Apollo Solar Turbo Charge Controller and when we applied the input voltage battery to the charge controller the display LCD sho

    Question – 3 comments

  24. Is there a solar PV field inspection check list?

    Asked 06/15/2011

    I'm looking forward to installing my first solar PV project, 5kW in California. Is there a checklist of the inspection?

    Question – 2 comments

  25. Does SMA Sunny Boy 10000TL-US operate on single phase 240V?

    Asked 06/15/2011

     I was wondering if the SMA10,000 is adjustable to single phase 240V?

    Question – 2 comments