9 Hole 1" Hub Strain Relief for #10 USE-2 Wires

QtyUnit PriceExtended Price
5$4.35$21.77
Description

Cord Connectors - Strain Relief

9 hole strain relief grip with 1" hub

  • Accommodates USE-2 12 AWG and 10 AWG wire
  • Skinned-over gland remains liquid tight, independent of the number of wires used
  • Skinned-over glands in the Solar Masthead II Cordgrips offer flexibility to use from 1 to 13 of the available holes while still providing a liquid tight seal around the wire.
  • Designed for solar rooftop installations.
  • Provides a watertight seal for PV module output leads to inverters.
  • Secures input PV leads from solar panel array strings to fuse holder hookup within solar combiner boxes.
  • Eliminates the need for combiner box in residential rooftop solar applications when appropriate threaded adaptor is used.
  • Generous wrenching flats for ease of assembly.
  • No disassembly required for installation.
  • UV resistant nylon construction with TPE or Buna N Sealing Gland resists salt water, weak acids, gasoline, alcohol, oil, grease, and common solvents.
 INSTALLATION INSTRUCTIONS for THREADED mounting holes:1. Be sure that hole is free of burrs and panel surface around hole is smooth and free of debris.2. Using the hex portion on the body (not the sealing nut), screw the fitting tightly into the threaded mounting hole.3. Insert the cable through the fitting to the desired position.4. Hand-tighten the SEALING nut as far as possible. Hold the BODY hex stationary with a wrench. Using a second wrench, tighten the SEALING nut until the wire is securely held in place.5. Using a wrench on the BODY hex, check to make sure the fitting is still screwed tightly into the panel.6. To disassemble for cable replacement, use a wrench to hold the BODY hex stationary and loosen the SEALING nut with a second wrench. Grip the disconnected cable and pull while turning the cable in the counter-clockwise direction.
General Information
Category:
Wire Management
Category:
PV connectors
Manufacturer:
Shipping Details
Ships Via:
UPS
Ship to Locations:
USA
Ship to Locations:
Canada
Ship to Locations:
Mexico
Shipping:
Will only ship - pickups are not accepted
Shipping Pricing:
Contact 1.800.409.2257 or email customer service for a freight quote
Return Policy
Return Policy:
Will accept returns
Item must be returned within:
30 Days
Refund will be given as:
Money Back
Return Policy Details:

Merchandise Return Policy - No returns will be accepted without prior authorization and must include the Return Material Authorization (RMA) number in order to return product. Any product that is returned must be brand new, in perfect condition and packaged in the original manufacturer's packaging with all hardware and documentation. Returns must be shipped with prepaid freight and insured via the carrier of your choice within 30 days of delivery. Upon receiving an RMA number, the CivicSolar representative will provide full shipping instructions. Shipping charges will not be refunded, unless, an error was made by CivicSolar in shipping. Before returning an item, you must have a RMA number. To obtain an RMA number, email Customer Service at: customerservice@civicsolar.com All returns are subject to a restocking fee. No returns will be accepted on installed items. No returns will be accepted beyond 30 days of original delivery.